15
Parameters
Reference mark
Maximum traverse path
Nominal increment
Interpolation
Inversion of reference mark
pulses
Reference point displacement
260
Explanation
Definition of the type of reference mark
Settings:
None: There is no reference mark
One: The encoder has one reference mark
Coded: The encoder has distance-coded reference marks
Default value: One
For linear encoders with coded reference marks:
maximum traverse path for determining the absolute position
Setting range: 0.1 mm ... 10000.0 mm
Default value: 20.0
For angle encoders with coded reference marks:
maximum nominal increment for determining the absolute
position
Setting range: > 0° ... 360°
Default value: 10.0
For encoders with TTL interface:
Interpolation value of the encoders and integrated interpolation
for the evaluation of the coded reference marks.
Settings:
None
2-fold
5-fold
10-fold
20-fold
50-fold
Default value: None
Specifies whether the reference mark pulses are evaluated in
inverted form
Settings
ON: Reference pulses are evaluated in inverted form
OFF: Reference pulses are not evaluated in inverted form
Default value: OFF
Configuration of the offset between the reference mark and the
zero point
Further information:
"Reference point displacement",
Page 261
HEIDENHAIN | ND 7000 | Operating Instructions Milling | 01/2020