HEIDENHAIN ND 7000 Operating Instructions Manual page 246

Milling
Table of Contents

Advertisement

15
15.4.3
USB
Path:
Parameter
Automatically detect attached
USB mass storage devices
15.4.4
Axes (switching functions)
Path:
In the Manual operation and MDI modes of operation, all axes or individual axes
can be reset to zero by setting the assigned digital input.
Parameter
General settings
<Axis name>
Position-dependent switching functions
15.4.5
Path:
The position-dependent switching functions enable you to set logical outputs
depending on the position of an axis in a defined reference system. Switching
positions and position intervals are available for this.
Parameter
Name
Switching function
246
Settings ► Interfaces ► USB
Settings ► Interfaces ► Switching functions ► Axes
Not all of the described parameters and options may be available,
depending on the product version, configuration and the connected
encoders.
Settings ► Interfaces ► Position-dependent switching functions ► +
Not all of the described parameters and options may be available,
depending on the product version, configuration and the connected
encoders.
Explanation
Automatic recognition of a USB mass storage device
Settings: ON or OFF
Default setting: ON
Explanation
Assignment of the digital input in accordance with the pin layout
in order to zero all axes
Default setting: Not connected
Assignment of the digital input in accordance with pin layout in
order to set all axes to zero
Default setting: Not connected
Explanation
Name of the switching function
Selecting whether the switching function should be activated or
deactivated
Settings: ON or OFF
Default setting: ON
HEIDENHAIN | ND 7000 | Operating Instructions Milling | 01/2020