132 Commissioning

"Configuration of Service Interface" Page

7.8.1.16
The settings for the service interface are shown on the "Configuration of the
Service Interface" page.

7.8.1.16.1 "Service Interface assigned to" Group

The application that the service interface is currently assigned to is displayed.
7.8.1.16.2 "Assign Owner of Service Interface (enabled after next controller
reboot)" Group
You can specify the application to which the service interface is assigned after
the next controller reboot.
Table 67: WBM "Configuration of Serial Interface RS-232" page – "Assign Owner of Service
Interface" Group
Parameters
WAGO Service
Communication
®
Linux
Console
Unassigned (usage by
applications, libraries,
CODESYS)
Click [Change Owner] to apply the change. The changes only take effect after
restarting the controller. For this purpose, use the WBM reboot function. Do not
shut down the controller too early!
Manual
Version 1.2.0, valid from FW Version 03.02.02(14)
750-8215 PFC200; G2; 4ETH CAN USB
Explanation
Specify that the service interface is used for the
WAGO Service communication or runtime system
communication.
Specify that the service interface is assigned to the
®
Linux
console.
Specify that the service interface is not to be
assigned to any application and is available, so that
the CODESYS program, for example, can access it
via function blocks.