Manuals and User Guides for WAGO 750-872. We have
1
WAGO 750-872 manual available for free PDF download: Quick Start Manual
WAGO 750-872 Quick Start Manual (44 pages)
ETHERNET Fieldbus Controller For Wago-I/O System 750, Modular I/O System
Brand:
WAGO
| Category:
Controller
| Size: 1 MB
Table of Contents
Table of Contents
3
1 Important Notes
4
Legal Principles
4
Copyright
4
Personnel Qualification
4
Intended Use
4
Symbols
5
Number Notation
5
Safety Information
6
Scope of Validity
6
2 Quick-Start Guide
8
Hardware Design
8
Fig. 1: Connections for the 750-872 Controller
8
Ethernet Network Start-Up
9
Fig. 2: Node with the 750-872 Telecontrol Fieldbus Controller
9
Fig. 3: WAGO Ethernet Settings
10
Fig. 4: Setting the PC Network Address under Windows
11
Fig. 5: IP Address Settings for the 750-872 Controller
12
Fig. 6: Testing the Connection to the 750-872 Telecontrol Controller with "PING
13
Installing the WAGO Target System for Codesys
14
Fig. 7: Users and Passwords of the 750-849 Controller's Web Server
14
Fig. 8: Installation of WAGO Target System for Codesys 1/2
14
Fig. 9: Installation of WAGO Target System for Codesys 2/2
14
Fig. 10: Properties for the Copy of Codesys V2.3
15
Telecontrol with Codesys 2.3
16
Fig. 11: Target System Settings
16
Fig. 12: WAGO-I/O-PRO CAA, PLC Configuration
16
Fig. 13: WAGO-I/O-PRO CAA, I/O Configuration
17
Fig. 14: WAGO-I/O-PRO CAA, I/O Configurator
18
Fig. 16: WAGO-I/O-PRO CAA, Variable Declaration in the I/O Configurator
19
Fig. 17: Adding IEC 60870-5 Config
19
Communication Via the RJ-45 Interface [TCP/IP]
20
Fig. 18: PLC Configuration
20
Fig. 19: IEC 60870 Settings - Config Ethernet
21
Fig. 20: Message Settings - Ethernet
21
Fig. 21: Setting the Variables for Ethernet Messages
22
Fig. 22: Settings - Ethernet Commands
22
Fig. 23: Task Configuration
23
Communication Via the Serial Interface
24
Fig. 24: IEC 60870 Settings - Config with Serial
24
Fig. 25: Settings for the Serial Interface in Codesys
25
Fig. 26: Message Settings - Serial
26
Fig. 27: Task Configuration Serial
27
Creating a Program
28
Fig. 28: the Program
28
Downloading the Program to the 750-872 Controller
29
3 Simulation
30
Simulating Telecontrol Via Ethernet (TCP/IP) with the Winpp104 Program
30
Fig. 29: Winpp104 Start Screen
30
Fig. 30: General Settings Winpp 104
31
Fig. 32: Parameterizing a Command Winpp104
32
Simulating Telecontrol Via the Serial Interface with the Winpp101 Program
33
Fig. 33: Detail of System Controller
33
Fig. 34: Winpp101 Start Screen
33
Fig. 35: General Parameters Winpp101
34
Fig. 36: Receiver / Transmitter Settings Page 1 Winpp101
34
Fig. 37: Receiver / Transmitter Settings Page 2 Winpp101
35
Fig. 38: Command Specification and Confirmation that the Command Has Arrived at the Controller
36
4 Appendix
37
Application Data Structure
37
Difference between Symmetrical and Asymmetrical Transmission Procedures
38
Fig. 40: Symmetrical Transmission Procedures of the Primary and Secondary Connection Layer
38
Fig. 41: Asymmetrical Transmission Procedure, Primary and Secondary Station
38
Explanation of the Set-Up Options for an Information Object
39
Fig. 42: Information Object Settings
39
Finding Incorrect Address Information with Codesys
40
List of Figures
41
Advertisement
Advertisement
Related Products
WAGO 750-880
WAGO 750-880/025-000
WAGO 750-806
WAGO 750-881
WAGO 750-843
WAGO 750-8215
WAGO 750-8202/040-000
WAGO 750-8202/040-001
WAGO 750-8111
WAGO 750-8112 Series