8E - 26
INSTRUMENT PANEL AND GAUGES
Fig. 4 Headlamp Switch
Removal
(4) Pull knob and stem assembly to stop. Depress
button on bottom of switch and remove knob and
stem from housing.
(5) Remove 2 screws and bezel from housing.
(6) Reverse removal procedures to install head
lamp switch.
GLOVE BOX LAMP SWITCH
(1) Open glove box until stops i n bin rest against
instrument panel.
(2) Grasp switch by plunger and pull firmly out
ward. Switch and lamp assembly are retained i n
mounting hole by a light snap fit (Fig. 5).
REMOVE
SCREWS
Fig. 5 Glove Box Lamp
Switch—Typical
(3) Disconnect wires to switch and lamp (Fig. 6).
(4) Remove bulb from socket.
(5) Reverse removal procedures to install switch
and lamp.
(6) Tuck any wiring that was exposed by lamp re
moval back into recess behind lamp. Do not leave
wires exposed i n glove box latch area.
•
Fig. 6 Glove Box Lamp and
Switch—Typical
OVERDRIVE LOCKOUT SWITCH
REMOVAL
(1) Remove cluster bezel (refer to Cluster Bezel Re
moval).
(2) Remove 3 screws and switch and bezel assem
bly (Fig. 7).
OVERDRIVE LOCKOUT
Fig. 7 Overdrive Lockout
Switch and Bezel
(3) Pull up on retaining tab and unplug electrical
connector.
INSTALLATION
(1) Position lockout switch into module and push
until retaining tabs lock into place.
(2) Connect switch connector.
(3) Install instrument cluster bezel to panel.