8A - 18
ELECTRICAL
•
FIELD
TERMINALS
TO POWERTRAIN
CONTROL MODULE.
TERMINAL 51
- A 1 4 2 -
10 AMP FUSE
A i l
GROUND
^ ^ B A T T E R Y
A
= = =
CHASSIS "
+
GROUND
J948A-17
Fig. 1 Generator Output Wire Resistance
Test (Typical)
(2) Adjust engine speed and carbon pile to main
tain 20 amperes flowing i n circuit. Observe voltmeter
reading. Voltmeter reading should not exceed 0.5
volts.
RESULTS
I f a higher voltage drop is indicated, inspect, clean
and tighten all connections between generator bat
tery terminal and battery positive post. A voltage
drop test may be performed at each connection to lo
cate connection with excessive resistance. I f resis
tance tested satisfactorily, reduce engine speed, turn
OFF carbon pile and turn OFF ignition switch.
(1) Disconnect negative cable from battery.
(2) Remove test ammeter, voltmeter, carbon pile,
and tachometer.
(3) Remove jumper wire.
(4) Connect generator output wire to generator
battery terminal post. Tighten to 5 to 6 N*m (45 to 75
in. lbs.).
(5) Connect negative cable to battery.
(6) Use DRB scan tool to erase DTC.
GENERATOR OUTPUT TEST
Generator output test determines whether genera
tor can deliver its rated current output.
PREPARATION
(1) Before starting any tests, make sure vehicle
has a fully charged battery. Test and procedures on
how to check for a fully charged battery are shown i n
Battery Test Procedures.
(2) Disconnect negative cable from battery.
(3) Disconnect generator output wire at the gener
ator battery terminal.
(4) Connect a 0-150 ampere scale D.C. ammeter i n
series between generator battery terminal and dis
connected generator output wire (Fig. 2). Connect
positive lead to generator battery terminal and neg
ative lead to disconnected generator output wire.
(5) Connect positive lead of a test voltmeter (range
0-18 volts minimum) to generator battery terminal.
(6) Connect negative lead of test voltmeter to a
good ground.
(7) Connect an engine tachometer and connect bat
tery negative cable.
(8) Connect a variable carbon pile rheostat be
tween battery terminals. Be sure carbon pile is i n
OPEN or OFF position before connecting leads. See
Load Testing i n Battery Test Procedures for instruc
tions.
(9) Connect one end of a jumper wire to ground
and with other end probe K20 lead wire at back of
generator (Fig. 2). This will generate a DTC.