6.4.3 Related Parameters

The following table lists parameters related to this function and their possibility of being changed while exe-
cuting this function or of being changed automatically after executing this function.
• Parameters related to this function
These are parameters that are used or referenced when executing this function.
• Allowed changes during execution of this function
Yes : Parameters can be changed using SigmaWin+ while this function is being executed.
No : Parameters cannot be changed using SigmaWin+ while this function is being executed.
• Automatic changes after execution of this function
Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.
Parameter
Pn160
Pn161
Pn162
Pn163
Pn164
Pn165
Name
Anti-Resonance Control Related Switch
Anti-Resonance Frequency
Anti-Resonance Gain Compensation
Anti-Resonance Damping Gain
Anti-Resonance Filter Time Constant 1 Compensation
Anti-Resonance Filter Time Constant 2 Compensation
6.4 Anti-Resonance Control Adjustment Function (Fn204)
Mid-execution
changes
Yes
No
Yes
No
Yes
Yes
Automatic
changes
Yes
Yes
No
Yes
No
No
6
6-31