YASKAWA JUSP-MD D01A Series User Manual page 347

For use with large-capacity models, design and maintenance, multi-winding drive unit, rotational motor, analog voltage and pulse train references, servopack, converter, servomotor
Table of Contents

Advertisement

10 Appendix
10.2.2 Parameters
Parameter
Size
No.
2
Input Signal Selection 4
4th 3rd 2nd 1st
digit digit digit digit
n.    
Pn50D
2
Output Signal Selection 1
4th 3rd 2nd 1st
digit digit digit digit
n.    
Pn50E
10-28
Setting
Name
Range
0000 to FFFF
/ZCLAMP Signal Mapping (Zero clamp when ON (closed))
0
Active when CN1-40 input signal is ON (closed).
1
Active when CN1-41 input signal is ON (closed).
2
Active when CN1-42 input signal is ON (closed).
3
Active when CN1-43 input signal is ON (closed).
4
Active when CN1-44 input signal is ON (closed).
5
Active when CN1-45 input signal is ON (closed).
6
Active when CN1-46 input signal is ON (closed).
7
Always active (fixed).
8
Not active (fixed).
9
Active when CN1-40 input signal is OFF (open).
A
Active when CN1-41 input signal is OFF (open).
B
Active when CN1-42 input signal is OFF (open).
C
Active when CN1-43 input signal is OFF (open).
D
Active when CN1-44 input signal is OFF (open).
E
Active when CN1-45 input signal is OFF (open).
F
Active when CN1-46 input signal is OFF (open).
/INHIBIT Signal Mapping (Reference pulse inhibit when ON (closed))
0 to F
Same as /ZCLAMP Signal Mapping.
/G-SEL Signal Mapping (Gain change when ON (closed))
0 to F
Same as /ZCLAMP Signal Mapping.
Reserved (Do not change.)
0000 to 3333
Positioning Completion Signal Mapping (/COIN)
0
Disabled (the above signal is not used.)
1
Outputs the signal from CN1-25, -26 output terminal.
2
Outputs the signal from CN1-27, -28 output terminal.
3
Outputs the signal from CN1-29, -30 output terminal.
Speed Coincidence Detection Signal Mapping (/V-CMP)
0 to 3
Same as /COIN Signal Mapping.
Servomotor Rotation Detection Signal Mapping (/TGON)
0 to 3
Same as /COIN Signal Mapping.
Servo Ready Signal Mapping (/S-RDY)
0 to 3
Same as /COIN Signal Mapping.
Factory
Units
When Enabled
Setting
8888
After restart
3211
After restart
(cont'd)
Classifi-
Reference
cation
Section
Setup
Reference
Section
5.3.5
Reference
Section
5.4.8
Reference
Section
6.7.6
Setup
Reference
Section
5.4.6
Reference
Section
5.3.8
Reference
Section
5.10.3
Reference
Section
5.10.4

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sigma-v seriesSgdv-j seriesSgmvvSgdv-coa

Table of Contents