5 Operation
5.8.3 Torque Limiting Using an Analog Voltage Reference
(1) Input Signals
Use the following input signals to limit a torque by analog voltage reference.
Type
Input
Refer to 5.5.1 Basic Settings for Torque Control.
(2) Related Parameters
Set the following parameters for torque limit by analog voltage reference.
Pn400
Pn402
Pn403
Pn415
5-58
Connector
Signal Name
Pin Number
T-REF
CN1-9
SG
CN1-10
Torque Reference Input Gain
Setting Range
Setting Unit
10 to 100
Forward Torque Limit
Setting Range
Setting Unit
0 to 800
Reverse Torque Limit
Setting Range
Setting Unit
0 to 800
T-REF Filter Time Constant
Setting Range
Setting Unit
0 to 65535
Torque reference input
Signal ground for torque reference input
Position
Speed
Factory Setting
30
0.1 V
(Rated torque at 3.0 V)
Position
Speed
Factory Setting
1%
800
Speed
Position
Factory Setting
1%
800
Speed
Position
Factory Setting
0.01 ms
0
Name
Torque
Classification
When Enabled
Immediately
Setup
Torque
Classification
When Enabled
Immediately
Setup
Torque
Classification
When Enabled
Immediately
Setup
Torque
Classification
When Enabled
Immediately
Setup