6 Adjustments
6.3.2 One-parameter Tuning Procedure
Step
8
9
10
11
6-18
Display after Operation
Keys
If readjustment is required, select the digit with the
or
Key or change the LEVEL with the
or
Key. Check the response.
If readjustment is not required, go to step 9.
Note: The higher the level, the greater the respon-
siveness will be. If the value is too large, how-
ever, vibration will occur.
• If vibration occurs, press the
winding drive unit will automatically detect the
vibration frequencies and make notch filter or an
anti-resonance control settings. When the notch fil-
ter is set, "NF1" or "NF2" will be displayed on the
bottom row. When the anti-resonance control is set,
"ARES" will be displayed in the lower right corner.
• If the vibration is great, the vibration frequency
will be detected automatically even if the
is not pressed and a notch filter or an anti-reso-
nance control will be set.
Press the
Key. A confirmation screen will be dis-
played after LEVEL adjustment.
• Press the
After the data is saved, "DONE" will flash for
approximately two seconds and then "RUN" will
be displayed.
• To return to the previous value, press the
• Press the
saving the values.
Press the
tuning operation. The screen in step 1 will appear
again.
Operation
Key. The multi-
Key to save the adjusted values.
Key to readjust the level without
Key to complete the one-parameter
(cont'd)
Key
Key.

Advertisement