Reading 32-Bit Data In Decimal Displays - YASKAWA JUSP-MD D01A Series User Manual

For use with large-capacity models, design and maintenance, multi-winding drive unit, rotational motor, analog voltage and pulse train references, servopack, converter, servomotor
Table of Contents

Advertisement

8 Monitor Displays (Un)
8.3

Reading 32-bit Data in Decimal Displays

The 32-bit data is displayed in decimal format. This section describes how to read the display.
Step
1
2
3
4
5
6
The method for reading the display is summarized below.
Upper 2 digits
The number of pulses between -2147483648 and 2147483647 is displayed continuously. When the number of
pulses is outside this range, the display will change as follows:
• The displayed value will change to 2147483647 when the number of pulses decreases by one from
-2147483648. Thereafter, the displayed value will decrease according to the number of pulses.
• The displayed value will change to -2147483648 when the number of pulses increases by one from
2147483647. Thereafter, the displayed value will increase according to the number of pulses.
8-4
Display after
Operation
MODE/SET
MODE/SET
Lower 4 digits
MODE/SET
Middle 4 digits
MODE/SET
Upper 2 digits
MODE/SET
MODE/SET
The display flashes to show the
digit position.
Middle
4 digits
Displayed for negative values.
Keys
Press the MODE/SET Key to select the monitor display.
DATA/
Press the UP or DOWN Key to display the parameter to be
displayed in 32-bit decimal.
In this example, "Un00D" is selected.
DATA/
Press the DATA/SHIFT Key for approximately one second.
The lower 4 digits of the setting of the selected parameter
are displayed.
DATA/
After checking the displayed digits, press the DATA/SHIFT
Key. The middle 4 digits of the setting of the selected
parameter are displayed.
DATA/
Press the DATA/SHIFT Key again. The upper 2 digits of the
setting of the selected parameter are displayed.
Note: If the DATA/SHIFT Key is pressed after the upper 2
digits are displayed, the lower 4 digits of the setting
DATA/
will be displayed again.
Press the DATA/SHIFT Key for approximately one second
to return to the display of step 2.
DATA/
Operation
Analog
Lower
4 digits

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sigma-v seriesSgdv-j seriesSgmvvSgdv-coa

Table of Contents