YASKAWA JUSP-MD D01A Series User Manual page 346

For use with large-capacity models, design and maintenance, multi-winding drive unit, rotational motor, analog voltage and pulse train references, servopack, converter, servomotor
Table of Contents

Advertisement

Parameter
Size
No.
2
Input Signal Selection 3
4th 3rd 2nd 1st
digit digit digit digit
n.    
Pn50C
Setting
Name
Range
0000 to FFFF
/SPD-D Signal Mapping
(Refer to 5.6 Internal Set Speed Control.)
0
Active when CN1-40 input signal is ON (closed).
1
Active when CN1-41 input signal is ON (closed).
2
Active when CN1-42 input signal is ON (closed).
3
Active when CN1-43 input signal is ON (closed).
4
Active when CN1-44 input signal is ON (closed).
5
Active when CN1-45 input signal is ON (closed).
6
Active when CN1-46 input signal is ON (closed).
7
Reserved (Do not use.)
8
Not active (fixed).
9
Active when CN1-40 input signal is OFF (open).
A
Active when CN1-41 input signal is OFF (open).
B
Active when CN1-42 input signal is OFF (open).
C
Active when CN1-43 input signal is OFF (open).
D
Active when CN1-44 input signal is OFF (open).
E
Active when CN1-45 input signal is OFF (open).
F
Active when CN1-46 input signal is OFF (open).
/SPD-A Signal Mapping
(Refer to 5.6 Internal Set Speed Control.)
0 to F
Same as /SPD-D Signal Mapping.
/SPD-B Signal Mapping
(Refer to 5.6 Internal Set Speed Control.)
0 to F
Same as /SPD-D Signal Mapping.
/C-SEL Signal Mapping (Control method change when ON (closed))
0 to F
Same as /SPD-D Signal Mapping.
Factory
Units
When Enabled
Setting
8888
After restart
10.2 List of Parameters
(cont'd)
Classifi-
Reference
cation
Section
Setup
Reference
Section
5.6.1
Reference
Section
5.6.1
Reference
Section
5.6.1
Reference
Section
5.7.1
10
10-27