(3) Example of Output Signal Allocation
The procedure to set Rotation Detection (/TGON) signal of factory setting to
Interlock (/BK) signal is shown below.
Pn50E
Display after
Step
Operation
1
2
3
4
Display flashes.
5
6
7
8
9
Display flashes.
10
11
To enable the change in the setting, turn the control power supply OFF and ON again.
(4) Checking Output Signals
Output signal status can be checked using the output signal monitor (Un006). As for the output signal monitor
(Un006), refer to 8.5 Monitoring Output Signals.
Pn50F
Before
After
Keys
Press the MODE/SET Key to select the parameter setting.
If a parameter other than Pn50E is displayed, press the UP
or DOWN Key to select Pn50E.
MODE/SET
DATA/
Press the DATA/SHIFT Key for approximately one second
to display the current data of Pn50E.
(/TGON is allocated on CN1-27 (28).)
MODE/SET
DATA/
Press the DATA/SHIFT Key to select the third digit from
the right. Press the DOWN Key to set "0."
(Sets /TGON "Invalid.")
MODE/SET
DATA/
Press the MODE/SET Key.
The data flashes and is saved.
MODE/SET
DATA/
Press the DATA/SHIFT Key for approximately one second
to return to the display Pn50E.
MODE/SET
DATA/
Press the UP Key to display Pn50F.
MODE/SET
DATA/
Press the DATA/SHIFT Key for approximately one second
to display the current data of Pn50F.
(/BK is set to "Invalid.")
MODE/SET
DATA/
Press the DATA/SHIFT Key to select the third digit from
the right. Press the UP Key to set "2."
(Allocates /BK to CN1-27 (28).)
MODE/SET
DATA/
Press the MODE/SET Key.
The value flashes and is saved.
MODE/SET
DATA/
Press the DATA/SHIFT Key for approximately one second
to return to the display Pn50F. /TGON is set as "Invalid"
and /BK is allocated on CN1-27 (28).
MODE/SET
DATA/
3.4 I/O Signal Allocations
Invalid
and allocate Brake
"
"
Operation