Step
Display after Operation
6
7
8
9
10
11
 With Determined Vibration Frequency
Step
Display after Operation
1
2
6.4 Anti-Resonance Control Adjustment Function (Fn204)
Keys
Press the
Key. The cursor will move to "damp,"
and the flashing of "freq" will stop.
Select the digit with the
the
or
Example of measured waveform
Note: Increase the damping gain from about 0% to
200% in 10% increments while checking the
effect of vibration reduction. If vibration reduc-
tion is still insufficient at a gain of 200%, can-
cel the setting, and lower the control gain by
using a different method, such as one-parame-
ter tuning.
If fine tuning of the frequency is necessary, press the
Key. The cursor will move from "damp" to
"freq." If fine-tuning is not necessary, skip step 9 and
go to step 10.
Select the digit with the
the
or
Press the
Key to save the settings. "DONE" will
flash for approximately two seconds and "RUN" will
be displayed.
Press the
Key to complete the anti-resonance
control adjustment function. The screen in step 1 will
appear again.
Keys
Press the
Key to view the main menu for the
utility function.
Use the
or
select Fn204.
Press the
Key to display the initial setting screen
for tuning mode.
(cont'd)
Operation
or
Key, and press
Key to set the damping gain.
Ro-
ta-
tion
Error
Error
Error
Torque reference
Torque reference
Torque reference
Positioning completed
Positioning completed
Positioning completed
signal
signal
signal
or
Key, and press
Key to fine-tune the frequency.
Operation
Key to move through the list,
6
6-27