YASKAWA JUSP-MD D01A Series User Manual page 264

For use with large-capacity models, design and maintenance, multi-winding drive unit, rotational motor, analog voltage and pulse train references, servopack, converter, servomotor
Table of Contents

Advertisement

(3) Operating Procedure
Use the following procedure to perform the gain adjustment of analog monitor output.
Display after
Step
Operation
1
2
3
4
5
6
7
8
9
10
7.9 Gain Adjustment of Analog Monitor Output (Fn00D)
Keys
Press the MODE/SET Key to select the utility function.
MODE/SET
DATA/
Press the UP or DOWN Key to select Fn00D.
MODE/SET
DATA/
Press the DATA/SHIFT Key for approximately one second.
The screen shown on the left will be displayed.
MODE/SET
DATA/
Press the DATA/SHIFT Key. Gain adjustment data will be
displayed as shown on the left.
MODE/SET
DATA/
Press the UP or DOWN Key to change the gain.
MODE/SET
DATA/
Press the DATA/SHIFT Key to return to the screen as
shown on the left.
MODE/SET
DATA/
Press the MODE/SET Key to switch to channel 2 (analog
monitor 2) monitor output.
MODE/SET
DATA/
Press the DATA/SHIFT Key. Gain adjustment data will be
displayed as shown on the left.
MODE/SET
DATA/
Press the UP or DOWN Key to change the gain.
MODE/SET
DATA/
Press the DATA/SHIFT Key for approximately one second.
"Ch2-G" is displayed, and then "Fn00D" is displayed again.
MODE/SET
DATA/
Operation
7
7-17

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sigma-v seriesSgdv-j seriesSgmvvSgdv-coa

Table of Contents