YASKAWA JUSP-MD D01A Series User Manual page 352

For use with large-capacity models, design and maintenance, multi-winding drive unit, rotational motor, analog voltage and pulse train references, servopack, converter, servomotor
Table of Contents

Advertisement

Parameter
Size
No.
Pn551
2
Analog Monitor 2 Offset Voltage
Analog Monitor
Pn552
2
Magnification (×1)
Analog Monitor
Pn553
2
Magnification (×2)
Remained Vibration
Pn560
2
Detection Width
Pn561
2
Overshoot Detection Level
Regenerative Resistor Capacity
Pn600
2
∗1
Pn601
2
Dynamic brake resistor capacity
SERVOPACK Ambient Tem-
Pn612
2
perature
Pn614
2
Servomotor Service Life 1
Pn615
2
Servomotor Service Life 2
Pn621 to
SERVOPACK: Safety Module
*3
Parameters
Pn628
∗1. Normally set to "0." When using an external regenerative resistor, set the capacity (W) of the regenerative resistor
unit.
∗2. The upper limit is the maximum output capacity (W) of the SERVOPACK.
∗3. These parameters can be set in SERVOPACKs with safety modules. For details, refer to
Safety Module (No.: SIEP C720829 06).
Setting
Name
Range
-10000 to
10000
-10000 to
10000
-10000 to
10000
1 to 3000
0 to 100
Depends on
SERVOPACK
Capacity
0 or higher
(Max. value
depends on
model.)
0 to 55
0 to 65535
0 to 65535
Factory
Units
Setting
0.1 V
0
×0.01
100
×0.01
100
0.1%
400
1%
100
10 W
0
∗2
10 W
0
∗2
1ºC
30
10 hours
500
10 hours
2000
10.2 List of Parameters
(cont'd)
Classifi-
Reference
When Enabled
cation
Section
Immediately
Setup
Immediately
Setup
Immediately
Setup
Immediately
Setup
Immediately
Setup
Immediately
Setup
Immediately
Setup
After restart
Setup
After restart
Setup
After restart
Setup
Σ
-V Series User's Manual,
6.1.3
6.1.3
6.1.3
6.5.1
6.2.1
6.4.1
3.8.3
3.9.2
10
10-33

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sigma-v seriesSgdv-j seriesSgmvvSgdv-coa

Table of Contents