YASKAWA JUSP-MD D01A Series User Manual page 51

For use with large-capacity models, design and maintenance, multi-winding drive unit, rotational motor, analog voltage and pulse train references, servopack, converter, servomotor
Table of Contents

Advertisement

 Converter
CN101
CN103,
CN104
1,
B1, B2
L1, L2, L3
Connectors/
Terminals
Main circuit power input termi-
L1, L2, L3
nals
CN101
Control power input connector
Main circuit DC voltage output
P, N
terminals
Ground terminal
Regenerative resistor connec-
B1, B2
tion terminals
DC reactor connection terminals
1,
2
CN103,
Control power output connectors
CN104
Converter
SGDV-COA5EDA
2
Name
Three-phase, 380 to 480 VAC, +10% to -15%, 50/60 Hz
24 VDC, ±15%
Mating connector model: 231-202/026-000 (Manufactured by
Connect these terminals to the P and N terminals on the SERVO-
PACK.
Connect this terminal to the power supply ground terminal and
then ground it.
Connect these terminals to the regenerative resistor unit.
Remove the short bar before you connect a DC reactor.
CN103 and CN104 output 24 VDC to the SERVOPACK.
The 24-VDC (±15%) input is output unaltered from CN103.
CN104 provides the same output, but it is normally not necessary
to connect it.
3.1 Main Circuit Wiring
P, N
Specifications
Wago Company of Japan, Ltd)
Pin 2: 24 V
Pin 1: 0 V
3
3-5

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sigma-v seriesSgdv-j seriesSgmvvSgdv-coa

Table of Contents