YASKAWA JUSP-MD D01A Series User Manual page 335

For use with large-capacity models, design and maintenance, multi-winding drive unit, rotational motor, analog voltage and pulse train references, servopack, converter, servomotor
Table of Contents

Advertisement

10 Appendix
10.2.2 Parameters
Parameter
Size
No.
Application Function Select
2
Switch 81
4th
digit
n.
Pn081
Pn100
2
Speed Loop Gain
Speed Loop Integral Time Con-
Pn101
2
stant
Pn102
2
Position Loop Gain
Pn103
2
Moment of Inertia Ratio
Pn104
2
2nd Speed Loop Gain
2nd Speed Loop Integral Time
Pn105
2
Constant
Pn106
2
2nd Position Loop Gain
Pn109
2
Feedforward Gain
Feedforward Filter Time
Pn10A
2
Constant
10-16
Name
0000 to 1111
3rd
2nd
1st
digit
digit
digit
Phase-C Pulse Output Selection
0
Outputs phase-C pulse only in forward direction.
Outputs phase-C pulse in forward and reverse direction.
1
Reserved (Do not change.)
Reserved (Do not change.)
Reserved (Do not change.)
Setting
Factory
Units
Range
Setting
10 to 20000
0.1 Hz
15 to 51200
0.01 ms
10 to 20000
0.1/s
0 to 20000
1%
10 to 20000
0.1 Hz
15 to 51200
0.01 ms
10 to 20000
0.1/s
0 to 100
1%
0 to 6400
0.01 ms
Classifi-
When Enabled
cation
0000
After restart
Setup
400
Immediately
Tuning
2000
Immediately
Tuning
400
Immediately
Tuning
100
Immediately
Tuning
400
Immediately
Tuning
2000
Immediately
Tuning
400
Immediately
Tuning
0
Immediately
Tuning
0
Immediately
Tuning
(cont'd)
Reference
Section
6.6.1
6.6.1
6.6.1
6.6.1
6.6.1
6.6.1
6.6.1
6.7.1
6.7.1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sigma-v seriesSgdv-j seriesSgmvvSgdv-coa

Table of Contents