Related Parameters - YASKAWA SGD7S-****20A Series Product Manual

Servopack with mechatrolink-iii communications references, ac servo drive
Table of Contents

Advertisement

6.11 Initializing the Vibration Detection Level

6.11.4 Related Parameters

6.11.4 Related Parameters

The following three items are given in the following table.
• Parameters Related to this Function
These are the parameters that are used or referenced when this function is executed.
• Changes during Function Execution
Not allowed: The parameter cannot be changed using the SigmaWin+ or other tool while this
function is being executed.
Allowed: The parameter can be changed using the SigmaWin+ or other tool while this func-
tion is being executed.
• Automatic Changes after Function Execution
Yes: The parameter is automatically set or adjusted after execution of this function.
No: The parameter is not automatically set or adjusted after execution of this function.
Parameter
Pn311
Pn312
Pn384
6-54
Name
Vibration Detection Sensitivity
Vibration Detection Level
Vibration Detection Level
Automatic
Setting Changes
Changes
Allowed
No
Not allowed
Yes
Not allowed
Yes