6.11 Initializing the Vibration Detection Level
6.11.4 Related Parameters
6.11.4 Related Parameters
The following three items are given in the following table.
• Parameters Related to this Function
These are the parameters that are used or referenced when this function is executed.
• Changes during Function Execution
Not allowed: The parameter cannot be changed using the SigmaWin+ or other tool while this
function is being executed.
Allowed: The parameter can be changed using the SigmaWin+ or other tool while this func-
tion is being executed.
• Automatic Changes after Function Execution
Yes: The parameter is automatically set or adjusted after execution of this function.
No: The parameter is not automatically set or adjusted after execution of this function.
Parameter
Pn311
Pn312
Pn384
6-54
Name
Vibration Detection Sensitivity
Vibration Detection Level
Vibration Detection Level
Automatic
Setting Changes
Changes
Allowed
No
Not allowed
Yes
Not allowed
Yes