Related Parameters - YASKAWA E-S Series Product Manual

Ac, dc power supply input and contact commands
Table of Contents

Advertisement

8.5.6

Related Parameters

The following parameters are automatically adjusted or used as reference when you execute
custom tuning.
Do not change the settings while custom tuning is being executed.
Parameter
Pn100
Pn101
Pn102
Pn103
Pn401
Pn408
Pn409
Pn40A
Pn40C
Pn40D
Pn140
Pn141
Pn143
Pn144
Pn145
Pn146
Pn147
Pn160
Pn161
Pn163
Yes: The parameter is automatically set.
No: The parameter is not automatically set, but the setting is read during execution.
Name
Speed Loop Gain
Speed Loop Integral Time Constant
Position Loop Gain
Moment of Inertia Ratio
First Stage First Torque Reference Filter Time Constant
Torque-Related Function Selections
First Stage Notch Filter Frequency
First Stage Notch Filter Q Value
Second Stage Notch Filter Frequency
Second Stage Notch Filter Q Value
Model Following Control-Related Selections
Model Following Control Gain
Model Following Control Bias in the Forward Direction
Model Following Control Bias in the Reverse Direction
Vibration Suppression 1 Frequency A
Vibration Suppression 1 Frequency B
Model Following Control Speed Feedforward Compensation
Anti-Resonance Control-Related Selections
Anti-Resonance Frequency
Anti-Resonance Damping Gain
8.5 Custom Tuning

8.5.6 Related Parameters

Automatic Changes
Yes
Yes
Yes
No
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
Yes
Yes
Yes
Yes
8
8-23

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sgpss servopackSgmsl servomotor

Table of Contents