11. OPTIONS AND AUXILIARY EQUIPMENT
11.12 Junction terminal block MR-TB26A
(1) Usage
When using a junction terminal block (MR-TB26A), always use it with a junction terminal block cable (MR-
TBNATBL M). To use a junction terminal block, mount it to the DIN rail.
Terminal numbers on a junction terminal block correspond with the pin numbers on the CN3 connector of a
servo amplifier. The terminal symbol S is for the shield.
Ground the junction terminal block cable using the S terminal of the junction terminal block.
(2) Specifications
Servo amplifier
Junction terminal block
Item
Rating
Twisted wire
Usable cables
Solid wire
Wire sheath outer diameter Wire with 3.4mm or less
Tool
Stripped length
Cable length
05: 0.5m
1 : 1m
CN3
Junction terminal block cable
(MR-TBNATBL M)
AC/DC32V 0.5A
0.08 to 1.5mm
0.32 to 1.2mm
210-619 (WAGO Company of Japan, LTD.) or equivalent
210-119SB (WAGO Company of Japan, LTD.) or equivalent
5 to 6mm
11 - 54
Junction terminal
MR-TB26A
2
(AWG28 to AWG14)
block
MR-TB26A