Table 9-5 Rj-61 Cable Connector - NEC Univerge SV9100 System Hardware Manual

Hide thumbs Also See for Univerge SV9100:
Table of Contents

Advertisement

Issue 3.0
14.2 Connector Pin-Outs on COIU Blade for Power Failure Circuits
14.3 Installing the Power Failure Telephones
SV9100 System Hardware Manual
Table 9-5 RJ-61 Cable
Connectorprovides the pin-outs for the RJ-61 cable
connector.

Table 9-5 RJ-61 Cable Connector

RJ-61 Cable Connector - CN13, SLT Interface for Power Failure
1.
Connect an RJ-61 connector to the COIU Blade installed in the system.
2.
Install a modular jack for each single line telephone supporting PF
operation. The modular jack should be within six feet of the phone.
3.
For each extension, run one-pair 24 AWG station cable from the
cross-connect block to a modular jack.
4.
Terminate the extension leads to GRN/RED of the modular jack. Terminate
the unused leads to the jack. Refer to
Connector (CN3) Shown on GCD-4COTB
Pin No.
Connection
1
2
3
Circuit 2 - Tip
4
Circuit 1 - Ring
5
Circuit 1 - Tip
6
Circuit 2 - Ring
7
8
Figure 9-151 Power Failure
Blade.