2.4
2.5
2.6
SV9100 System Hardware Manual
Uninstalling a Blade Slot Through Software
The installer can turn off (busy out) and delete (remove from software) blade slots
in the Controlling and Expansion Chassis in programming for port renumbering or
to replace it with a different blade. Deleting a blade may affect blade slot
programming ability. Refer to Program 90-05 in the UNIVERGE SV9100
Programming Manual for detailed information.
Blade Capacities
The universal architecture of the UNIVERGE SV9100 provides flexibility when
installing blades. With the exception of the GCD-CP10, GPZ-BS10, and
GPZ-BS11 blades, any blade can be installed in any slot.
Maximum 9.5" Gateway and 19" System Capacities – Blades on page 2-12
Table 2-7 SV9100 Maximum 9.5" Base and Expansion System Capacities –
Blades on page 2-14
provide a list of the blades and the maximum capacities with
various chassis configurations.
Powering Up the SV9100 System
2.6.1
Performing a Cold Start
This section describes the process for starting the system (19" and 9.5"
chassis) for the first time or starting a system that has been turned off.
CAUTION
To perform a cold start:
1.
Turn the system power off.
2.
Once the system has powered down, push in and hold the Load
button.
3.
Turn the power switch back on to power the system back up.
With a multi-chassis system, turn on the Expansion Chassis
power supply, then the Controlling Chassis power supply.
4.
Continue holding the Load button for approximately three seconds or
until LED 2 starts flashing red.
5.
Release the Load button.
6.
When the system has completed reloading the software (two
minutes), the Status LED is flashing on the GCD-CP10.
IMPORTANT CONSIDERATIONS
System software is loaded from flash memory, and customer
data is from RAM memory.
To avoid extension and trunk renumbering, if certain blades
are recognized first, remove them from their respective slots
until the system has been reset. Then, slot the blade cards in
the correct order to retain the proper system numbering. (Use
Program 10-03 prior to performing a cold start to record the
current slot definitions.)
Table 2-6 SV9100