Table 4-18 Gpz-4Lca/Gpz-8Lce/ Rj-61 Cable Connector Pin-Outs - NEC Univerge SV9100 System Hardware Manual

Hide thumbs Also See for Univerge SV9100:
Table of Contents

Advertisement

Issue 3.0
SV9100 System Hardware Manual
Each CN2 (GPZ-4LCA
provides connection to four analog station ports and is not polarity sensitive.
The GPZ-8LCE consumes eight ports ranging between ports 001~256
(remember that the GCD-8LCA consumes eight ports).
Refer to the following tables for maximum upgrade capacity of the
GPZ-4LCA/GPZ-8LCE SLI daughter board:
Table 2-6 SV9100 Maximum 9.5" Gateway and 19" System
Capacities – Blades on page 2-12
Table 2-7 SV9100 Maximum 9.5" Base and Expansion System
Capacities – Blades on page 2-14
4.4.2
Installation
CAUTION
This daughter board can be installed on the GCD-4LCA or GCD-8LCA
blade.
To install the GPZ-4LCA
1.
Four plastic spacers are Included with the GPZ-4LCA/GPZ-8LCE.
Install the plastic spacers on either the GCD-4LCA or GCD-8LCA.
Make sure to attach the spacers so that they extend out on the side of
the daughter board which has the CN1 connector. Refer to
4-17 Installing the GPZ-4LCA/GPZ-8LCE Daughter Board on page
4-44.
2.
Position the GPZ-4LCA
connector on the GCD-4LCA/GCD-8LCA blade. Press the blade and
board together, ensuring the plastic spacers lock in place. Refer to
Figure 4-17 Installing the GPZ-4LCA/GPZ-8LCE Daughter Board on
page
4-44.
3.
Install the GCD-4LCA/GCD-8LCA blade in the slot in the chassis.
4.4.3
Connectors
Table 4-18 GPZ-4LCA/GPZ-8LCE/ RJ-61 Cable Connector Pin-Outs on
page 4-46
show the pin-outs for the RJ-61 connector.
the GPZ-4LCA/GPZ-8LCE Daughter Board on page 4-44
location of the connectors on the GPZ-4LCA
/
GPZ-8LCE) or CN3 (GPZ-8LCE only) connector
When connecting a fax machine or analog modem, make
sure to set Program 15-03-03 to 1 (special terminal) to
avoid communication problems.
The GCD-4LCA/GCD-8LCA blade and the GPZ-4LCA/
GPZ-8LCE daughter board are categorized as TNV2. With
this designation, off-premise wiring is not acceptable. Any
cabling to these blades or daughter boards must be in the
building – no outside cabling is permitted.
Branch connection is not acceptable.
/
:
GPZ-8LCE
/
GPZ-8LCE CN1 connector over the CN4
Figure
Figure 4-17 Installing
shows the
/
GPZ-8LCE daughter boards.
4-45