Install a modular jack for each PGD(2)-U10 ADP. For each module,
run one-pair 24 AWG station cable from the cross-connect block to a
modular jack. Ground the unused pair.
4.
Terminate the extension leads to GRN/RED of the modular jack.
Terminate the unused leads to the jack.
5.
Install bridging clips as required.
6.
Plug a modular line cord from the mod jack to the CN1 connector on
the PGD(2)-U10 ADP.
7.
Connect the two-conductor station cable from the CN5 connectors in
the PGD(2)-U10 ADP to the external relay.
NOTE

Figure 9-14 GCD-CP10 Page Connections

R
S
ECORDING
External Recording System or External Ringer
The PGD(2)-U10 ADP allows the connection of an external recording system or
external ringer. With a customer-provided tape recorder, when an extension user
dials the ACI analog port extension number, they can automatically start the
recorder and activate the record function. When the user hangs up, the recording
stops and the tape recorder turns off. For tape recording, connect the tape
recorder AUX input jack to the PGD(2)-U10 ADP jack. Connect the recorder
control leads (if available) to the CTL (control relay) jack. By using Department
Calling, you can arrange multiple tape recorders into a pool. When an extension
user dials the Department Group pilot number, they reach the first available tape
recorder in the pool.
The relay closes when the Door Box/external page
zone is called. The maximum applied voltage is 24vDC
at .5A for each contact.