Slot Locations
Each CHS2UG-US has six slots. In the Controlling Chassis, the GCD-CP10 (for
Key Systems) must be installed in the first slot (slot 1). In the CHS2UG GW-US
and CHS2UG B-US, the GCD-CP10 must be installed in the first slot (slot 1).
Slot Locations in the CHS2UG-US (19" Controlling Chassis):
Slot 1 – dedicated for the CPU
Slots 2~6 – universal
Slot Locating in the CHS2UG-US (19" Expansion Chassis):
Slots 1~6 are universal. (i.e., any type of blade except the CPU can be installed
in these slots).
Slot Locations in the CHS2UG GW-US and CHS2UG B-US Base (9.5" Chassis):
Slot 1 – CPU
Slots 2 and 3 – universal
Slot Locations in the 9.5" CHS2UG B-US and CHS2UG E (Controlling Chassis
with CPU):
Slot 1 – CPU
Slots 2~6 – universal
Slot Locations in the 9.5" CHS2UG B-US and CHS2UG E (Expansion Chassis no
CPU):
Slots 1~6 – universal