Verifying And Backing Up Parameter Settings; Verifying And Backing Up Parameter Settings; Parameter Access Level: A1-01; Password Settings: A1-04, A1-05 - YASKAWA J1000 Technical Manual

Compact v/f control drive
Hide thumbs Also See for J1000:
Table of Contents

Advertisement

4.8 Verifying and Backing Up Parameter Settings

4.8

Verifying and Backing Up Parameter Settings

Check changes to parameter settings using the Verify function.
page
66.
Save the verified parameter settings. Change the access level or set a password to the drive to prevent accidental modification
of parameter settings.
u

Parameter Access Level: A1-01

Setting the Access Level for "Operation only" (A1-01 = 0) allows the user to access parameters A1-oo and Uo-oo only.
Other parameters are not displayed.
No.
Parameter Name
Access Level
A1-01
Selection
u

Password Settings: A1-04, A1-05

The user can set a password to the drive to restrict access. The password is selected via parameter A1-05. The selected password
must be entered in parameter A1-04 to unlock parameter access (i.e., parameter setting A1-04 must match the value
programmed into A1-05). The following parameters cannot be viewed or edited until the value programmed into A1-04
correctly matches the value as programmed in parameter A1-05: A1-01 and A1-03.
Note:
Parameter A1-05 is hidden from view. To display A1-05, access parameter A1-04 and simultaneously depress the
key.
u

Copy Function (Optional)

Parameter settings can be copied to another drive to simplify parameter restoration or multiple drive setup. The RS-232C
Interface Unit (Removable Type) (SI-232/JC) is required to use the following options with J1000 drives:
n
USB/Copy Unit (JVOP-181)
The copy unit is an external option connected to the drive to copy parameter settings to another drive. It includes a USB adapter
to connect the drive to a PC.
n
LED Operator (JVOP-182)
The LED operator operates the drive and supports copying, importing, and verifying parameter settings.
Note:
Use of the LED operator requires that the drive is running drive software version PRG: 1010 or later.
n
Drive Wizard Plus
Drive Wizard Plus is a PC software tool for parameter management, monitoring, and diagnosis. Drive Wizard Plus can load,
store, and copy drive parameter settings. For details, refer to Help in the Drive Wizard Plus software.
The installation files can be obtained at no charge from:
U.S.: http://www.yaskawa.com
72
Selects which parameters are accessible via the digital operator.
0: Operation only (A1-01 and A1-04 can be set and monitored. U parameters can be
monitored)
2: Advanced Access Level (All parameters can be set and monitored)
http://nicontrols.com
Refer to Verifying Parameter Changes: Verify Menu on
Description
YASKAWA ELECTRIC SIEP C710606 31B YASKAWA AC Drive – J1000 Technical Manual
Setting
Default
Range
0, 2
2
key and the

Hide quick links: