12.5.36 0x6092/n Feed constant
Index Sub-index
0x6092
0
1
2
Object works in:
•
Motion Control:
All modes
o
Object 0x6092
tions.
Feed
constant
Parameter
=
The allowed value for 0x6092/2
than 1 results in an SDO abort response.
Writing to object
command to parameter
If object 0x6092/1 or 0x6092/2 was written and then a save parameters command
(object 0x1010) processed, the object value is stored in non-volatile memory.
After the next power on of the inverter, the previously set value is reactivated and
overwrites the setting of parameter
The values of Object 0x6092/1 and 6092/2 are limited as follows:
No.
0x6092/1 Feed
0x6092/2 (Driving) shaft revolutions
98
Meaning
Highest sub-index supported
Feed
(Driving) shaft revolutions
feed constant
defines the feed (in user units) per driving shaft revolu-
0x6092/1
=
driving
0x6092/2
1115
Feed
Constant
1
driving shaft revolutions
feed
driving shaft revolutions
or
Feed Constant
Parameter
Object
CM-EtherCAT
Data type
Unsigned8
Unsigned32
Unsigned32
Object doesn't work in:
Non motion Control (conf. ≠ x40)
•
feed
shaft
revolution
is 1 only. Writing values other
automatically generates a write
1115 (data set 5, all data sets in RAM only!).
1115.
Feed constant
Min.
1
1
Access
Map
Def.-Val
ro
No
2
rw
No
0x1 0000
rw
No
1
s
Setting
Max.
65535
(= 0x0000 FFFF)
1
07/13