12.4.13 0x3111/0 Ref. Value Word 1
Index Sub-index
0x3111
0
Via object 0x3111 it is possible to write to a Word source like parameter
Word 1
The value of object 0x3111 is available as source which can be chosen by the selec-
tion of "762 - CANopen 0x3111 Ref. Value" from a parameters choice list.
12.4.14 0x3112/0 Ref. Value Word 2
Index Sub-index
0x3112
0
Via object 0x3112 it is possible to write to a Word source like parameter
Word 1
The value of object 0x3112 is available as source which can be chosen by the selec-
tion of "763 - CANopen 0x3112 Ref. Value" from a parameters choice list.
58
Meaning
Ref. Value Word 1
950 of the Systembus.
Meaning
Ref. Value Word 2
950 of the Systembus.
CM-EtherCAT
Data type
Access
Unsigned16
rw
Data type
Access
Unsigned16
rw
Map
Def.-Val
Rx
0
TxPDO1
Map
Def.-Val
Rx
0
TxPDO1
07/13