Function Sdo; Error Code Table - BONFIGLIOLI Vectron ACTIVE CUBE Series Manual

Ethercat communication module cm-ethercat frequency inverter 230 v / 400 v
Hide thumbs Also See for ACTIVE CUBE Series:
Table of Contents

Advertisement

11.3

Function SDO

The SDO (Service Data Objects) messages are used for reading and writing the
objects located in the object dictionary.
11.3.1

Error code table

If an error occurs in reading or writing, the server SDO of the frequency inverter re-
plies with the SDO abort message.
Abort code
high
0x0601
0x0602
0x0604
0x0606
0x0607
0x0607
0x0607
0x0609
0x0609
0x0609
0x0609
0x0800
0x0800
28
Error codes
Abort code
Description to CANo-
®
low
pen
0x0000
Unsupported access to an
object
0x0000
Object does not exist
0x0047
General internal incom-
patibility in the device
0x0000
Access failed due to a
hardware error
0x0010
Data type does not match -
0x0012
Data type does not match
or length of Service tele-
gram too big
0x0013
Data type does not match
or length of Service tele-
gram too small
0x0011
Subindex does not exist
0x0030
Value range of parameter
exceeded
0x0031
Value of parameter written
too high.
0x0032
Value of parameter written
too low.
0x0020
Data cannot be transmit-
ted or saved
0x0021
Data cannot be trans-
ferred because of local
control
CM-EtherCAT
Product-specific allocation
Parameter cannot be writ-
-
ten or read
Parameter does not exist
-
Data sets differ
-
EEPROM Error
-
(Read/write/checksum)
Parameter has a different
data type
Parameter has a different data
type or telegram length not
correct.
Parameter has a different data
type or telegram length not
correct.
Data set does not exist
-
Parameter value too large
-
or too small
Parameter value too large
-
Parameter value too small
-
Invalid value for operation
-
parameter cannot be writ-
-
ten in operation
07/13