lnstallation
A 3-7
Connecting
the
Air Supply
Follow
this procedure to connect the air supply to your unit.
1.
See Figure A 3-4. lnstall the air pressure regulator, gauge, and filter
that
were shipped with your unit.
2.
Turn
the regulator fully counterclockwise
(off).
NOTE:
Noidson recommends installing
a
shutoff
valve with a
lock-out
in
the air supply line
to
isolate
the unit from the air supply for
maintenance procedures.
3.
Connect a supply of
clean, dry air to the input air fitting or shutoff
valve.
NOTE:
To
achieve
the rated adhesive output of the unit, you must
connect
a plant air supply that is capable of providing the maximum
air pressure
specified on the
unit. The
maximum
air pressure is either
483 kPa (70 psi) or 620 kPa (90 psi), depending upon the type of
pump
your unit
has.
To
find
the maximum air pressure for your unit,
check
the air pressure tag, which is located next to the inlet air
port,
above
the hose connectors.
4130014A
Fig. A
3-4
Installing the
Air
Pressure Regulator,
Gauge, and
Filter
e000
Nordson
Corporation
All
rights reserved
41-3000v
lssued
5/00
A3EN-04-[3V-X-4XXVj-1 3