A
3-20
lnstallation
Connecting Output Contacts
(Optional)
@ontd1
WARNING:
Risk of
equipment damage, personal
injury
or
death.
For
a proper and safe installation, make sure you meet
the requirements
in
the
following step.
6.
See Figure A
3-12.
Route
the output contact wires
(2)
through the
strain relief
(1)
to
terminal block TB2
(3).
Make sure
your installation
meets
these requirements:
.
Use
0.34-0.25
mm2
(22-24
AWG) stranded wire
that is suitable
for National Electrical Code (NEC) Class
1
remote
control and
signaling
circuits.
Output
contacts are rated for 250 VAC, 2 A
maximum.
Use
the proper length
of
wire and route the wires so they do not
touch any of the printed circuit
boards.
Make sure the
wires reach
terminal block TB2 when the electrical enclosure is opened.
a
1
2
3
dt
aooraa
Fig. A
3-12
Connecting
Output
Contacts
1.
Strain
relief
3.
TB2
terminal
block
2.
Output
contact wires
A3EN-04-[3V-X-4XXVI-1 3