Page 1
DC gear (O, R, S, T, U, or W) Manifold 4-Port (A or J) 6-port (B, C, K, L, O, or P) 2-port (R, U, S, or T) Control MultiScan (3) E 2000 Nordson Corporation B3EN-03-[3-TANK]-3 41-3000 All rights reserved Issued 9/00...
Page 2
B 3-0 Tank and Manifold E 2000 Nordson Corporation B3EN-03-[3-TANK]-3 41-3000 All rights reserved Issued 9/00...
Page 3
(RTD) or thermostat. Parts includes illustrated parts lists for the melter and all major assemblies. Refer to this section for the part number of any component that needs to be replaced. E 2000 Nordson Corporation B3EN-03-[3-TANK]-3 41-3000 All rights reserved...
Page 4
Like the grid, it has a cast-in heater and an RTD and overtemperature thermostat that sense the tank temperature and provide input to the control system. E 2000 Nordson Corporation B3EN-03-[3-TANK]-3 41-3000 All rights reserved...
Page 5
5. Turn off the melter; disconnect and lock out electrical power to the melter at the branch circuit disconnect switch, and disconnect and lock out electrical power supplied through any I/O wiring. E 2000 Nordson Corporation B3EN-03-[3-TANK]-3 41-3000 All rights reserved...
Removing the Hopper from the Grid 1. Hopper 3. Grid 2. O-ring 6. Check the gasket on top of the hopper. If it is not damaged, you do not need to replace it. E 2000 Nordson Corporation B3EN-03-[3-TANK]-3 41-3000 All rights reserved Issued 9/00...
Page 7
4. Remove the screws on the bottom of the hose-end panel. Swing the panel and wire harness away from the melter. E 2000 Nordson Corporation B3EN-03-[3-TANK]-3 41-3000 All rights reserved...
Page 8
Return the melter to the level position. NOTE: Ask an assistant to help you tilt the melter and support it while you remove the screws and washers. E 2000 Nordson Corporation B3EN-03-[3-TANK]-3 41-3000 All rights reserved...
Page 9
3. Turn the manifold upside down and align it correctly on the reservoir. NOTE: If the O-rings are lubricated, they will stay in the grooves when you turn the manifold upside down. E 2000 Nordson Corporation B3EN-03-[3-TANK]-3 41-3000 All rights reserved...
Page 10
Figure B 3-4. 9. Reconnect the ground wire (if present) to the reservoir. 10. If the melter was attached to a support platform, anchor it to the platform now. E 2000 Nordson Corporation B3EN-03-[3-TANK]-3 41-3000 All rights reserved...
Page 11
9. Attach the ground wire to the rear panel of the melter. Slide the panel into place and secure it with the captive screws. 10. Lubricate a new O-ring with O-ring lubricant and place it in the groove on top of the grid. E 2000 Nordson Corporation B3EN-03-[3-TANK]-3 41-3000 All rights reserved...
2. Install and secure the pump cover. 3. Piston pump and MPC melters: Return the pump air pressure to the normal operating setting. 4. Remove the lock-out and restore power to the melter. E 2000 Nordson Corporation B3EN-03-[3-TANK]-3 41-3000 All rights reserved...
14–16 NSm (10–12 ft-lb). 5. Refill the tank with adhesive and resume normal operation. 4130835 Fig. B 3-7 Replacing the Pressure Control Valve (typical) 1. Pressure control valve 2. Tank E 2000 Nordson Corporation B3EN-03-[3-TANK]-3 41-3000 All rights reserved Issued 9/00...
5. Resume normal operation. 4130836 Fig. B 3-8 Drain Valve Components 1. Alignment screw 3. Drain valve 2. Washer E 2000 Nordson Corporation B3EN-03-[3-TANK]-3 41-3000 All rights reserved Issued 9/00...
Page 15
8. Restore air and power to the melter and resume normal operation. 4105077A Fig. B 3-9 Replacing Other Manifold Valves 1. Circulation control valve 3. Air-piloted pressure control valve 2. Pressure control valve E 2000 Nordson Corporation B3EN-03-[3-TANK]-3 41-3000 All rights reserved Issued 9/00...
Page 16
B 3-14 Tank and Manifold E 2000 Nordson Corporation B3EN-03-[3-TANK]-3 41-3000 All rights reserved Issued 9/00...