Resistance Temperature Detector (RTD) Fault
Nordson offers two test plugs that simplify the troubleshooting of
RTD
faults. These test
plugs help
you quickly and easily determine whether
the problem is
a
gun, hose, or tank RTD problem or a control system
problem.
Refer
to
Partstor the kit part number.
When
the
FAULT
light
And the Selector
display
And the
Multipurpose
display
It means
Do
this
Flashes
for
two minutes
then stays
on
continuously
(See Note A)
Shows
a
zone
number (refer to
Table
B
2-4)
Flashes RTD
(See
Note
B)
rLd
The RTD or RTD
circuit of the
indicated
zone is
open or shorted.
Refer
to
Checking
an RTD or
RT
D
Ci rcu
it
in
Trou
b
I
e
shooti
ng
Procedures.
NOTE
A:
When
the
FAULT
light
flashes, the warning output contact is open and the fault output contact
is
closed.
After
a
two-minute delay, the warning output contact closes and the fault output contact opens. When
the
FAULT
light
is
off, both output
contacts are
closed.
For
more information on these output contacts,
refer
to
Connecting
Output Contacts in lhe lnstallafion section.
B:
The
actual-temperature display will show 260
'C
(500
'F)
if
the
RTD is open
the RTD is shorted.