Maintenance
A5-7
Cleaning
a
Standard
Manifold
Filter
Fig. A
5-6
Loosening
the
Filter
c,,,",*
6.
lncrease
the pump air pressure
by
turning the air pressure regulator
clockwise until
a
clean, steady flow of adhesive flows from the drain.
Allow adhesive to
flow until no traces of char are present.
7.
Return
the pump air pressure to
0.
8.
Close
the manifold drain valve.
9.
Return
the pump air pressure to the operating setting.
Use
this procedure to clean the manifold
filter.
Cleaning the
filter
removes excess dirt and
charred material that can clog the system and
cause poor system performance
WARNING: Hot!
Risk
of
burns. Wear heat-protective
clothing,
safety goggles, and heat-protective
gloves.
Hot
melt material
may
be released under pressure.
1.
Ensure that
the unit is at operating temperature.
2.
Flush
the manifold
filter.
Refer
to
Flushing
a Standard Manifold Filter
in
this section.
WARNING: System or
material
pressurized.
Relieve pressure.
Failure
to observe may result in serious burns.
3.
Relieve
system
pressure.
Refer
to Relieving System
Pressure
in
this
section.
4.
See
Figure
A
5-6.
Loosen
the filter using
a
wrench.
A
socket-type
wrench is recommended.
@898