Series 3000V lnput/Output
Board
E 1-9
4.
l/O Board Replacement
Use
this procedure to replace a defective l/O board with a new l/O board
WARNING:
Risk of equipment
damage, personal
injury or
death. Disconnect and
lock out
electrical power to the unit,
including inpuVoutput
(liO)
lines.
1.
Turn
off
the unit; then disconnect and lock out electrical power to the
unit,
including l/O lines.
2.
Open
the electrical
enclosure.
Refer
to
Opening
and Closing the
Electrical Enclosure in
lhe
Control section.
3.
Remove
the screw that holds the board
to
its bracket inside
the
electrical enclosure.
NOTE: A new bracket
is
included
in
the
service
kit.
lf desired, you
can replace the existing bracket with this new bracket.
4.
Label
or note existing connections for later reference, then disconnect
wires from the board and pull the board out of the XP5 card edge
connector.
5.
Remove
the new board from its static-safe container, making sure to
handle
the board by its edges without touching pins, wires, or
circuitry.
6.
Carefully
installthe new
board
in
the XPS
card edge connector and
attach
the board to the bracket with the screw provided
in
the seruice
kit.
Tighten
the screw to
2.03-2.26 N.m (18-20
in.-lb).
7.
Reconnect wires to
the new l/O
board.
Refer to Table E
1-1
(standard l/O boards)
orTable
E 1-2
(enhanced l/O boards)
in
I
n
put/O
utp
ut
Co
n
necti ons
f
or termi
nal
con
nections.
8.
Close and
secure the electrical
enclosure.
Refer
to
Opening
and
Closi
ng the Electrical
Enclosu
re in
lhe
Control section.
9.
Restore power to
the unit and resume normal operation.
@