Nordson 3100V Series Customer Product Manual page 372

Hot melt material applicator with 6:1 sp30 piston pump and vista'controller
Hide thumbs Also See for 3100V Series:
Table of Contents

Advertisement

Low Level
lndicator
E 2-1
Section
E
2
Low Level lndicator
1.
lntroduction
WARNING:
Allow only
qualified personnelto perform the
following
tasks.
Observe and follow
the safety instructions
in
this
document and all other related documentation.
The low level indicator sends
a
signal
to an external device when the
adhesive level
in
the applicator's tank is low. The external device can
be
a Nordson vacuum hopper feeder that automatically adds more adhesive,
or
a
customer-supplied light that warns operators when the adhesive
level is
low.
The low level indicator consists of
a
float, counterweight, lever
rod,
mercury switch and
terminal block. The float is balanced by the
counterweight to ride half in and half out of the hot melt material. As the
adhesive level drops, the float attached to the lever rod drops down. The
mercury switch attached to
the lever
rod
tilts
forward. This
action causes
the mercury switch to close and activates the terminal block.
The indicator is intended for 30 VAC maximum, Class 2 circuit operation
as
defined in Article 725
ot
the National ElectricalCode.
Gtr)97
Nordson
Corporalion
All ,ights
reserved
41-3000v
lssued
6/97
E2EN-03-[3V-LLll-4

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3400v series3500v series3700v series

Table of Contents