A
3-38
lnstallation
To
Program All Zones to the Same Temperature
Follow
this procedure to set all zones to the same temperature. Also use
this procedure along with the procedure
To
Program Setpoint and
Standby Temperatures lndividually to set most zones to the same
temperature.
NOTE: This
procedure
works only for zones that have been previously
turned
on.
The default setting for all zones is OFF.
To
turn
a
zone
on,
refer to
the previous procedure,
To
Program Setpoint and Standby
Temperatures lndividually, and set
the temperature of each zone you
want to
turn on to at least 38
'C
(100
'F).
1.
lf
you have not already done so, turn power
on
to
the unit by pressing
the
POWER switch.
2.
See Figure A 3-22. ln the System Setup area, press the Move Up
(1)
and Move Down (2) keys until the SETPOINT or STANDBY light turns
on.
The system defaults to the internal-zone type and the INTERNAL
light
turns on.
NOTE:
lf
you have enabled the password feature, you must change
the.number
in
the Multipurpose display (500) to the password (321)
and press
the Enter key before the system will allow you to change
any
of
the
temperature setpoints.
I
lweruBE
-Hr
O
fro**
lSt
r-,
-E-E
EI
J
smrM
1
2
4130305A
Fig.
A3-22
Selecting the
Set
All Feature
(System Setup Area)
'1.
Move
Up
key
2.
Move
Down key
A3EN-04-[3V-X-4XXVj-1 3
41-3000v
lssued 5/00
@
2000
Nordson
Corporalion
All
dghts reserved