these guidelines when programming temperature settings:
Check
the Manufacturer's Safety Data Sheet (MSDS) for the
recommended operating temperature
of
the adhesive that
you will
use.
For a zone
to be on, the operating temperature must be set at
38
'C
(100 "F) or
higher.
Set
the standby temperature 56 "C (100
'F)
lower than the
operating
temperature.
Before programming any
temperature settings, make sure that the
overtemperature setpoint is at least 14 "C
(25'F)
higher than
the
highest
operating setpoint
used.
Refer to
Table
A 3-5, Feature No.
3.
Use this tip
to program temperature settings quickly:
a
a
Zone
Procedure
All
zones to the same
temperature
Most
zones to the same
temperature
Follow
the procedure
To
Program
All
Zones to the Same Temperature.
1.
First, follow
the procedure
Io
Program All
Zones to the Same
Temperature.
2.
Then, follow the procedure
Io
Program Setpoint and
Standby
Te