Series 3000V lnput/Output
Board
E 1-T
3.
Additional
Features
6.
Close and secure
the electrical
enclosure.
Refer
to
Opening
and
Closi
ng the Electrical
Enclosu re
in
lhe
Control section.
7.
Restore power to
the unit and resume normal operation
The l/O board adds the following additional features that can
be
programmed using the SYSTEM SETTINGS controls:
o
Auto Standby
Tlmeout
.
ln Standby Timeout
o
Remote Heaters
On/Remote Pump Enable
.
Rempote Pattern
Select (Pattern control units only)
Each
feature
is
factory-set at zero (0), which means the feature is
disabled.
To
program these
features, refer
to Programming SYSTEM
SE77INGS
Controlsinlhe lnstallation section.
Refer to Table E
1-3
for a
description of how each feature works and a range of possible settings.
Table E
1-3
SYSTEM SETTINGS
Timeout Features
Feature No.
Feature
Description
Default
Setting
Optional
Settings
30
Auto Standby
Timeout
Allows you
to program the unit to automatically
enter the
standby mode and maintain heated
zones at standby temperature setpoints if a gun
is not
fired during the specified period of time.
The unit will remain
in
standby mode indefinitely
unless
a
gun
is
fired or unless
a
value other than
zero (0) is entered in Feature 31, ln Standby
Timeout.
0
(setting
is
off)
0-1440
(minutes)
31
ln Standby
Timeout
Allows you
to program the unit to automatically
exit the
standby mode and enter the sleep mode
(turn
the heaters off)
if
a
gun is
not
fired during
the specified period
of
time.
0
(setting is off)
o-1440
(minutes)
34
Remote
Heaters
On/Remote
Pump Enable
Allows you
to remotely turn heaters on or to
enable/disable
the
pump. This feature
is only
available on
the enhanced l/O board.
0
(Remote
Heaters On)
0
(Remote
Heaters On)
1
(Remote
Pump Enable)
51
Remote
Pattern
Select
(Pattern
control units
only)
Allows
a pattern to
be
selected
through
the liO
board.
lf this
feature
is
set
to
1 or
2, patterns
can be selected via inputs on the l/O board.
Refer to Table
E
1-4lor
the
various settings.
This
feature is only available on the enhanced
l/O board.
0
(setting is
off)
1or2
@