A
5-20
Maintenance
To
Restore the Unit to Normal Operation
After
flushing your system with hot melt material,
a
flushing material, or
Type
R
fluid, follow this procedure
to
restore
your unit to normal
operation.
1.
Disconnect and lock out electrical power to the unit.
2.
Reconnect each gun to its hose both electrically and mechanically
Refer
to Mechanical lnstallation
and
Electrical
lnstallationinlhe
lnstallation section
of
this manual.
3.
Remove
the lock-out and restore power to the unit.
4.
lf
you have changed the unit's temperature setpoints or
if
the
recommended operating temperature
of
the new adhesive is different
from the previous adhesive, reprogram the temperature settings.
Refer
to
System
Programming
Proceduresinlhe
lnstallation section
of
this manual.
5.
Use
a metal or plastic scoop to fill the tank with
adhesive.
Refer
to
Filling the
Tank
with
Adhesiveinthe
lnstallation
section of this
manual.
6.
Return
the pump air pressure to the operating setting
7.
Resume normal operation