3-36
lnstallation
To
Program Setpoint and Standby Temperatures lndividually
Follow
this procedure to set the setpoint and standby temperatures for
each zone.
1.
lf
you have not already done so, turn power on to the unit by pressing
the POWER switch.
2.
ln
the System Setup area, press the Move Up and Move Down keys
until
the SETPOINT or STANDBY light turns
on.
The system defaults
to
the internal zone type and the INTERNAL light turns
on.
NOTE:
lf
you have enabled the password feature, you must change
the number
in
the Multipurpose display (500) to the password (321)
and press
the Enter key before the system will allow you to change
any
of
the
temperature setpoints.
3.
lf you want
to select the hose-zone type or the gun-zone type instead
of
the internal-zone type, press the Move Right key until the light
beneath
the zone type you want to set turns
on.
4.
See Figure A
3-21
.
ln
the Displays area, press the Up key (1) below
the Selector display (2) until the zone number you want appears on
the display. (Refer to Table A 3-7.) The Multipurpose display
(3)
changes
to show the current temperature setting for the zone you
selected.
5.
ln
the Displays area, press the Up or Down key
(
) below the
Multipurpose display to change
the temperature. The display flashes.
NOTE:
Pressing
the Up or Down keys
in
the Displays area once
changes
the number shown in increments of
one.
Pressing
and
holding
the key changes the number in increments
of
five.
A3EN-04-[3V-X-4XXVj-1
3
41-3000v
lssued 5/00
@000
Nordson Corporation
All rights reseNed