B
2-2O
Control
Checking the
480 Vac
Distribution Board Harnesses
and the Transformer
Follow
this procedure to check the harnesses on the 480 VAC distribution
board and the transformer.
WARNING:
Risk of
equipment damage, personal injury or
death.
Disconnect and lock out electrical power to the unit,
including inpuVoutput
(l/O) lines.
1.
Place
the unit's POWER switch
in
the off position, disconnect and
lock
out electrical power to the unit at the branch circuit disconnect
switch, and disconnect and lock out electrical power supplied through
any l/O wiring.
2.
Open
the electrical enclosure. Refer to Opening and Closing the
Electrical Enclosure.
3.
Use
an ohmmeter to check the continuity of the harnesses connected
to
the following connectors on the 480 VAC distribution board and
take action as directed. See Figure
B
2-4tor
the location of
connectors on boards.
Harness
Connector
Check continuity
across harness
pins...
Continuity
exists?
Action
480 VAC
distribution board to
transformer primary winding
X1D
1
and3
No
Replace
the harness.
Yes
Go to
the
ne)d
step.
480 VAC
distribution board to
transformer secondary
winding
x1D
6and8
No
Replace
the harness
Yes
Go to
the next step.
480 VAC
distribution board to
TBlA
and
TB1
B
x3D
2and4
No
Replace
the harness
Yes
Go to
the
nelt
step.
82
EN-04-[3V-X-4XXVj-5