26
ProBlue Flex OEM User's Guide
Pressure Type
Manual pressure
adjustment, analog
gauge (default)
Manual pressure
adjustment, digital
gauge (Touch screen
optional)
Electronic pressure
adjustment and
Pressure Runup (Touch
screen optional)
Part 1129255_01

Manually Adjusting the System Air Pressure

The following table describes the default and optional pressure monitoring
and adjustment options.
Manually adjust the system pressure using a 5mm hex wrench. Use the gauge
to help define the system air pressure you want.
S
Adjust the system pressure through the PLC.
S
Using BBconn Cloud, touch screen and/or the PLC, set high and low
pressure limits and a target pressure set point.
NOTE: Pressure settings are stored within saved recipes.

To manually adjust system air pressure

See Figure 7. Using a 5mm hex wrench, turn the pressure adjustment screw
clockwise to increase pressure and counterclockwise to decrease pressure.
Figure 5
Manual pressure adjustment
1. Optional pressure gauge
What you can do...
2
1
2. Manual pressure adjustment
screw