Hydraulics
B 1-29
Cleaning or Replacing the
Magnet Assembly
4.
lnstallthe
actuator with
the screws and washers you removed earlier
Tighten
to
3-4
N.m
(28-36
in.-lb).
5.
Apply Teflon paste
or
tape to
the air line elbow threads; then install
the elbow
in
the actuator.
6.
Connect
the air input line to the actuator
7.
Replace
the pump cover, restore power and air to the unit, and
'
resume operation.
Use
this procedure to clean or replace the magnet assembly. The
magnet
assembly is located inside the actuator.
Magnet Assembly Removal
WARNING:
Disconnect and lock
out line voltage to the unit.
Failure
to obserue this warning can result in personal injury or
death.
1.
Turn
the unit
off;
then disconnect and lock out power to the unit.
2.
Reduce
the pump air pressure to
0.
3.
Remove
the pump cover.
4.
Disconnect the
air input line from the actuator.
5.
Remove
the actuator:
a.
Move
the hydraulic shaft up or down until shifter fork is centered
in
the pump mount.
b.
Remove the screws and washers
that secure the actuator; then
remove
the actuator.
NOTE:
Series 3100t4
3400t4 and
3500Vunits have
a pump
cover bracket that must be
removed. See Figure B
1-19.
@
2000
Nordson Corporalion
All
dghts
reserved
41-3000v
lssued
5/00
81
EN-02-[3V-X-AGXXI-2