Lnstalling The Solenoid Valve - Nordson 3100V Series Customer Product Manual

Hot melt material applicator with 6:1 sp30 piston pump and vista'controller
Hide thumbs Also See for 3100V Series:
Table of Contents

Advertisement

B
1-38
Hydraulics
Removing the Solenoid
Valve
(contd)
lnstalling the
Solenoid
Valve
5
1
4
2
4130834A
Fig. B
1-26
Solenoid
Valve
Assembly Components
1.
Plug
4.
Elbows
2.
Mounting
block
5.
Air
lines
3.
Screws
Follow
this procedure to install the new solenoid valve.
1.
See Figure B
1-26.
lnstall
the elbows on the new solenoid valve.
2.
lnstall
the solenoid valve and mounting block on the back panel
of
the
unit with
the screws you removed earlier.
3.
Connect
the air lines to the solenoid valve elbows.
4.
Connect
the solenoid valve plug.
5.
Close
the electrical enclosure and restore power to the unit.
6.
Return
the
pump
air pressure to the normal operating setting.
7.
Start
the unit and listen for air
leaks.
lf
you hear air leaking, check the
air line connections at the elbows.