Control
B 2-7
lnternal,
Hose,
or
Gun
Zone Not
Heating
Closing
1.
Reconnect any ground wires that
were disconnected during
troubleshooting or repair activities.
2.
Raise the control-end
frame into place and tighten the captive screws
on each side
of
the
frame.
You may need
to pull the front and rear
covers apart
to position the frame.
3.
Position
the electrical enclosure lid on top of the unit and secure it
with
the captive screws.
4.
Remove
the lock-out and restore power to the system
lf
a
tank, hose, or gun will not heat, use this troubleshooting table.
Problem
Possible Cause
Corrective Action
lnternal, hose, or gun zone
not heating
Zone setpoint temperature below
38'C
(100'F)
Check
the setpoint temperature for the
zone. The
setpoint
temperature must be
38
'C
(100
"F)
or above
forthe
zone to
heat.
Refer
lo
Programming
T
E M
P
E
RAT
U
R
E
Co
ntrols
in
lhe
lnstallation section to program setpoint
temperatures.
@
2000
Nordson
Corporation
All
rights
reserved
41-3000y
lssued
5/00
82EN-04-[3V-X-4XXU-5