Control
B
2-31
4.
See Figure
B
2-7.
Remove
the fuse from the fuse holder and install
the new
fuse.
Refer to
the following table.
Fuse
Holder
To Remove
To
lnstall
Vertical
1.
Press
down
on
the
fuse
cap and turn it
counterclockwise until
you feel
the cap
release.
2.
Lift
the cap and fuse
from
the connector.
1.
Pull the
fuse from the
cap and replace
it
with
a new fuse.
2.
lnsert
the cap and
fuse into the fuse
holder.
Turn the
fuse
and
cap clockwise
and press down until
you
feelthe cap
lock
into place.
Horizontal
Lift the fuse
from
its
two-station connector
Press
the replacement
fuse into the two-station
connector until the fuse
snaps into place.
2
o
O
4130079A
Fig.
B
2-7
Fuse
Holders
'1.
Vertical
2.
Horizontal
3.
Close
the electrical
enclosure.
Refer
to
Opening
and Closing the
Electrical Enclosure.
e000
Nordson
Corporalion
All righls
reserved
41-3000v
lssued
5/00
82EN-04-[3V-X-4XXV]-5