Nordson 3100V Series Instruction Sheet

Level switch
Hide thumbs Also See for 3100V Series:

Advertisement

Quick Links

Setup Instructions for Series 3100V Level Switch
1. Introduction
2. Installation
Assembling the Low-Level
Switch
E 2000 Nordson Corporation
All rights reserved
WARNING: Allow only qualified personnel to perform the
following tasks. Observe and follow the safety instructions in
this document and all other related documentation.
When the adhesive level in the Series 3100V melter is low, the low-level
switch magnetically closes a dry reed switch which is connected to an
external device. The external device can automatically add more
adhesive or illuminate a light that warns operators when the adhesive
level is low.
The low-level switch consists of a float switch, shield, and terminal block.
The float rides half in and half out of the adhesive. As the adhesive level
drops, the float drops, signaling the terminal block.
The switch is intended for 30 VAC maximum, 30 W, less than 0.28 A,
Class 2 circuit operation as defined in Article 725 of the National
Electrical Code.
WARNING: Hot! Risk of burns. Wear heat-protective clothing,
safety goggles, and heat-protective gloves. Hot melt material
may be release forcefully.
Follow this procedure to assemble the low-level switch
321 355A
Issued 5/00
Instruction Sheet
P/N 321 355A
41- -3000- -IS- -65

Advertisement

loading

Summary of Contents for Nordson 3100V Series

  • Page 1 2. Installation safety goggles, and heat-protective gloves. Hot melt material may be release forcefully. Assembling the Low-Level Follow this procedure to assemble the low-level switch Switch 321 355A 41- -3000- -IS- -65 E 2000 Nordson Corporation All rights reserved Issued 5/00...
  • Page 2 3. Use the two flat-head screws (7) to attach the shield (8) to the base. 4. Use the pan-head screws (3) and lock washers (4) to fasten the switch to the pump pan. See Figure 2. 41- -3000- -IS- -65 321 355A E 2000 Nordson Corporation All rights reserved Issued 5/00...
  • Page 3: Preparing For Installation

    4. Remove the screws holding the pump pan to the tank cover. 5. Clean the tank of all debris; then remove the pump, pan, tank cover, and gaskets. 321 355A 41- -3000- -IS- -65 E 2000 Nordson Corporation All rights reserved Issued 5/00...
  • Page 4 8. Gasket, tank cover 3. Wire leads 6. Terminal block, 4 station 9. Customer external device wires 2. Reinstall the pump and reconnect the air supply. 41- -3000- -IS- -65 321 355A E 2000 Nordson Corporation All rights reserved Issued 5/00...
  • Page 5 3. Clean any debris from the tank; then fill the adhesive to within 25 mm (1 in.) of the top of the tank. 4. Turn the unit on and wait for the READY light to illuminate. 321 355A 41- -3000- -IS- -65 E 2000 Nordson Corporation All rights reserved Issued 5/00...