Automatically Shutting Down The Unit; Manually Shutting Down The Unit; System Monitoring Procedures - Nordson 3100V Series Customer Product Manual

Hot melt material applicator with 6:1 sp30 piston pump and vista'controller
Hide thumbs Also See for 3100V Series:
Table of Contents

Advertisement

A
4-6
Operation
Automatically Shutting Down
the Unit
Manually Shutting Down the
Unit
3.
System
Monitoring
Procedures
lf
the CLOCK light is on and the system is programmed to turn the
heaters off automatically,
the system willshut itself down.
Use
this procedure to shut the unit down manually at any time.
1.
Press
the PUMP key. The
PUNIP
light will
turn off and the pump will
stop.
2.
Place
a
container under all guns and trigger the guns to relieve
system pressure.
3.
Shut
down all guns as follows:
.
Air-operated guns: turn off the operating
air.
o
Electric guns:
turn off the gun driver.
.
Hand-operated guns: lock the trigger.
4.
Piston
pump
units only:
turn
off
the pump air pressure.
5.
Press
the HEATERS key. The HEATERS light willturn off
This part of lhe Operafion section contains the following system
monitoring procedures:
o
Checking
the zone temperatures
.
Checking
the programmed settings
.
Checking the
fault log
.
Running
a
system
test
See Figure A 4-1 for the Vista operator panel keys and displays